• PORTABLE FIRE PUMP SYSTEM

    PORTABLE FIRE PUMP SYSTEM

    • Fully complies with UL -864 and NFPA-72.
    • Rugged CRCA sheet with powder coated finish.
    • Operates on 110 – 220VAC 50 /60 Hz, AC mains power supply.
    • 16×2 Dot Matrix LCD display.
    • 4/8 Class B Style ?B ? or Style ?C? Initiating Device Circuit (IDC).
    • All zones accept smoke detectors and normal open contact devices.
    • Any zone can be configured as alarm or supervisory zone.
    • 2 Class B Notification Appliance Circuits (NAC).
    • NAC shall be programmed as silenceable or non-silenceable.
    • Supervisory zone shall be latching or resettable.
    • Standby (battery) backup 24VDC power supply with built in charger.
    • Error free Fire / Fault status in unambiguous colored LED indication.
    • System ON indication.
    • Main & Standby status with audible and visual indication.
    • Battery low visual warning with audible tone.
    • Form C relays for fire, fault and supervisory.
    • Resettable / Steady 24VDC Output.
    • RS 485 Communication facility (Optional).
    • Lamp test facility.
    • All field wiring circuits are power limited except 110-220VAC and battery.
    • All field wiring circuits are supervised.
    • Walk test facility.
    • Zone isolation facility with loop voltage cut off.
    • Earth fault annunciation facility at 0 ohms.
    • AC low voltage cutoff.
    • Programmable AC loss delay.
    • Programmable alarm verification.
    • Programmable trouble reminder.
    Special Features
    • Switched Mode Power Supply.
    • Modular Construction.
    • Auto Resettable Fuse.
    • Surge Protection for all Input and outputs.
    • Battery polarity reversible protection.
    • Surface Mount Technology.
    • Over all current consumption is low.

    PORTABLE FIRE PUMP SYSTEM

    55,500.00
  • Commercial Dough Toast Moulder Roller

    Brand:JTS

    Power: 0.75Kw
    Rated Voltage/Frequency: 220V/60Hz
    Dimensions: 1350*650*1180mm
    Toast Dough Moulder
    Rolls, stretches, and rolls dough after mixing.
    ease your bakery work with our machine.
    fast and reliable.
    High quality product that is suitable for commercial use.

    44,000.00
  • 2 zones aspirating fire detection system

    2-ZONE ASPIRATING FIRE DETECTION SYSTEM

    Cirrus HYBRID is the only aspirating detector available to identify the optically invisible fire particulate by utilizing the unique ‘Cloud Chamber Detection’ (CCD) technology.

    Combined Cloud Chamber ‘Fire’ and optical ‘Smoke’ detection

    History tells us that in reality there are really only two types of aspirating detector technology. These technologies are ‘Cloud Chamber’ aspirating detection identifying optically invisible fire particulate, and laser or LED ‘Optical’ aspirating detection identifying small amounts of visible smoke.

    Depending on the materials burning, particularly in the many modern applications for aspirating detection systems, some fires burn with only a small amount of visible smoke, whereas others burn with greater volumes of visible smoke.

    Cirrus HYBRID detects these wide-ranging ‘smokier’ fire types too. Early Warning Smoke Detection (EWSD) is provided using high performance optical ‘Scatter Chamber Detectors’ (SCD) that identify both small and larger smoke particles entering the detector.

    By utilising the two most effective methods of aspirating system technologies (CCD and EWSD) in a single detector the Cirrus HYBRID detector provides a device able to detect fire and smoke over the largest range of fire types.

    However, what makes this totally new and genuinely unique concept in aspirating fire and smoke detection technology so different is that these two technologies work both independently from each other, and through the use of complex algorithms also interact together, to provide true intelligent alarm decision making. The result of this synergy of technologies is a device that can verify true alarm conditions across the largest range of fire types. A further and equally as important result of this synergy of technologies, is the discrimination of unwanted or false alarms which have historically and still continue to plague so many optical only aspirating detectors.

    2 zones aspirating fire detection system

    38,500.00
  • ALTAIR® 5X Multigas Detector

    Brand:JTS

    The ALTAIR 5X Gas Detector is capable of measuring up to 6 gases simultaneously and is now available with integrated PID sensor for VOC detection. Driven by advanced MSA XCell® Sensor Technology, the ALTAIR 5X Gas Detector delivers faster response time, better stability, accuracy, longer service life, and cost savings over the life of the instrument.

    32,899.9033,500.00

    ALTAIR® 5X Multigas Detector

    Brand:JTS
    32,899.9033,500.00
  • ALTAIR® 4X Multigas Detector

    Brand:JTS

    The ALTAIR 4X is an extremely durable Multigas Detector that simultaneously measures up to four gases from a wide range of XCell(R) sensor options including combustible gases, O₂, CO, H₂S, SO₂ and NO₂. The ALTAIR 4X Detector surpasses industry standards in several crucial areas. Its four-year sensor life is 60% longer than the industry average, while its 24-hour run time exceeds the industry average by 71%. This versatile portable detector is a perfect match for industries ranging from fire fighting to welding, and its digital sensor output makes it less likely to suffer from RF interference. The unit features exclusive MotionAlert™, which lets others know if the user has become immobile, and InstantAlert™, a manual alarm that alerts others of potentially dangerous situations. This rugged unit is designed to withstand a drop of up to 20 ft (6m) and uses less than half as much calibration gas as the industry average.

    17,800.0018,800.00

    ALTAIR® 4X Multigas Detector

    Brand:JTS
    17,800.0018,800.00
  • ALTAIR® 4XR Multigas Detector

    Brand:JTS

    Outfitted with rapid-response MSA XCell® sensors, the ALTAIR 4XR Gas Detector is the toughest 4-gas monitor on the market and is backed by a 4-year warranty. The ALTAIR 4XR can also provide real-time incident awareness to team members, supervisors, safety managers and others when paired with the MSA ALTAIR Connect app via a Bluetooth® wireless connection.

    17,600.00
  • ASENWARE EXTINGUISHING CONTROL PANEL

    ASENWARE EXTINGUISHING CONTROL PANEL
    Product overview

    The AW-GEC2159 Automatic gas extinguishing control panel is a combined fire alarm control panel and extinguishing system and has 4 detection zones, any or all of which are capable of contributing to the extinguishing release decision.

    Gas fire extinguishing controller for use in gas automatic fire extinguishing system, automatic detection, automatic alarm, automatic fire extinguishing controller, gas fire extinguishing controller can connect to the smoke and heat detector, the emergency stop button, automatic transfer switch, spray gas lamp, sound and light alarm devices, such as provide drivers and electromagnetic valve, used to start the gas fire extinguishing equipment.
    Product Features

    Features: 

    1. Emergency stop: In delay time and found to have abnormal situation, does not need to start the fire extinguishing system, according to the manual control box or gas extinguishing controller of the emergency stop button, can prevent controller extinguishing instruction.

    2. Networking: Gas fire extinguishing controller also can connect with fire alarm controller, a remote control.
    3. Application:
    a)Electrical and electronic equipment;
    b) Can burn liquid and can melt the solid fire;
    c) Solid surface fire;
    d)Can cut off the gas source gas fire extinguishing before.
  • INDUSTRIAL EVACUATION MANUAL SIREN

    INDUSTRIA EVACUATION MANUAL SIREN

    Technical Details

    Brand Saladulce
    Product Dimensions 5.91″L x 5.12″W x 10.96″H
    Voltage 220 Volts
    Noise Level 120 dB
    Manufacturer Saladulce

    About this item

    • 【Loud alarm】The horen is made into arc shape, which will spread the sound wave effectively. The sound inbuilt can alarm once it is touched. The volume can reach up to 120dB.
    • 【Great flash】The siren adopts 18 luminous lamp beads, low power consumption and long service life. Also it is designed with diffuser, which can flash in the dark light.
    • 【Outdoor tool】The alarm adopts waterproof material and premium sheel. Especially suitable for outdoor installation.
    • 【Note】1) The machine need to do some wiring, comes without plug switch. 2) The alarm comes without on switch. If you would like to turn off, please cut off the power. 3)The volume and tone can not be adjusted for this model.
    • 【Application】 Industrial LED acousto-optic alarm range: for crane, gantry crane, bridge crane, crane, tunnel construction, metallurgy, ports, construction site, school security, security etc.

    INDUSTRIAL EVACUATION MANUAL SIREN

  • FIRE EXTINGUISHING CONTROL PANEL

     

     

    Item specifics

    Condition
    New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is … 
    Brand
    Ravel
    Type
    Fire Alarms
    Model
    Fire Alarm Control Panel
    MPN
    2554
    Country/Region of Manufacture
    India

    Item description 

    Fully complies with UL -864 and NFPA-72.

    • Rugged CRCA sheet with powder coated finish.
    • Operates on 110 – 220VAC 50 /60 Hz, AC mains power supply.
    • 16×2 Dot Matrix LCD display.
    • 4/8 Class B Style ?B ? or Style ?C? Initiating Device Circuit (IDC).
    • All zones accept smoke detectors and normal open contact devices.
    • Any zone can be configured as alarm or supervisory zone.
    • 2 Class B Notification Appliance Circuits (NAC).
    • NAC shall be programmed as silenceable or non-silenceable.
    • Supervisory zone shall be latching or resettable.
    • Standby (battery) backup 24VDC power supply with built in charger.
    • Error free Fire / Fault status in unambiguous colored LED indication.
    • System ON indication.
    • Main & Standby status with audible and visual indication.
    • Battery low visual warning with audible tone.
    • Form C relays for fire, fault and supervisory.
    • Resettable / Steady 24VDC Output.
    • RS 485 Communication facility (Optional).
    • Lamp test facility.
    • All field wiring circuits are power limited except 110-220VAC and battery.
    • All field wiring circuits are supervised.
    • Walk test facility.
    • Zone isolation facility with loop voltage cut off.
    • Earth fault annunciation facility at 0 ohms.
    • AC low voltage cutoff.
    • Programmable AC loss delay.
    • Programmable alarm verification.
    • Programmable trouble reminder.
    Special Features
    • Switched Mode Power Supply.
    • Modular Construction.
    • Auto Resettable Fuse.
    • Surge Protection for all Input and outputs.
    • Battery polarity reversible protection.
    • Surface Mount Technology.
    • Over all current consumption is low.

    FIRE EXTINGUISHING CONTROL PANEL

  • HANDING TYPES fm200

    HANDING TYPES fm200

    An FM 200 fire suppression system is a clean agent fire suppression solution that uses a colorless, odorless gas called FM-200 (heptafluoropropane) to extinguish fires. Unlike water-based systems, FM 200 systems are designed to quickly suppress fires without causing damage to sensitive equipment or leaving any residue.

    How Do FM 200 Fire Suppression Systems Work?

    FM 200 systems are designed to detect and suppress fires in their early stages. Here’s a step-by-step look at how they operate:

    1. Detection: Advanced smoke and heat detectors continuously monitor the protected area. If they detect a fire, the system is activated.
    2. Activation: Upon activation, the FM-200 gas is rapidly discharged into the room or enclosed space. This typically happens within 10 seconds.
    3. Suppression: The FM-200 gas absorbs the heat from the fire and disrupts the chemical reaction occurring in the flames. This effectively extinguishes the fire.
    4. Ventilation: After the fire is suppressed, ventilation systems are used to clear the FM-200 gas from the area, making it safe for re-entry.

    Benefits of FM 200 Fire Suppression Systems

    There are several key advantages to using an FM 200 system over traditional fire suppression methods:

    Rapid Response

    FM 200 systems can suppress a fire in seconds, significantly reducing the potential for damage and downtime.

    Equipment Safety

    Since FM-200 is a clean agent, it won’t harm sensitive electronics, valuable documents, or other critical assets. This makes it ideal for use in data centers, archives, and museums.

    No Residue

    Unlike water or foam-based extinguishers, FM-200 leaves no residue behind, eliminating the need for extensive clean-up after a discharge.

    Safe for Occupied Spaces

    FM 200 is non-toxic at concentrations used for fire suppression, making it safe for use in areas where people are present.

    Applications of FM 200 Gas Suppression Systems

    FM 200 systems are versatile and can be used in various environments, including:

    • Data Centers: Protecting servers and networking equipment from fire without damaging the electronics.
    • Telecommunication Facilities: Ensuring uninterrupted communication by safeguarding equipment.
    • Archives and Libraries: Preserving valuable documents, books, and artifacts.
    • Healthcare Facilities: Protecting sensitive medical equipment and records.
    • Museums and Art Galleries: Ensuring that irreplaceable artworks and exhibits are not damaged by fire suppression efforts.

    Choosing the Right FM 200 System

    When selecting an FM 200 fire suppression system, it’s essential to work with a knowledgeable provider who can tailor the system to your specific needs. Here are some factors to consider:

    • Room Size and Layout: The size and configuration of the space will determine the amount of FM-200 gas needed and the placement of nozzles.
    • Type of Assets: Different assets may have varying protection requirements.
    • Regulatory Compliance: Ensure that the system meets all relevant fire safety regulations and standards.

    Maintenance and Inspection

    Regular maintenance and inspection of your FM 200 fire extinguishing systems are crucial to ensure they function correctly in an emergency. This typically involves:

    • Routine Checks: Regularly scheduled inspections by qualified technicians.
    • System Testing: Periodic testing to verify that detectors, alarms, and discharge mechanisms are operational.
    • Refilling and Servicing: Ensuring that the FM-200 gas cylinders are fully charged and ready for use.

    HANDING TYPES fm200

  • FIRE HOSE REEL CABINET

    Description

    Flammable Cabinet, Safety Cabinet Type Standard, Capacity 30 gal, Height 44 in, Width 43 in, Depth 18 in, Safety Cabinet Door Type Manual, Number of Cabinet Shelves 1, Color Yellow, Number of Doors 2
    6,500.007,500.00
  • Stainless Steel Combination Safety Shower with Eye Wash

    Brand:JTS

    6250 SS
    Stainless Steel Combination Safety Shower with Eye WashProduct Code
    6250 SS

    SAFETY SHOWER/EYE WASH – Pull Rod Hand/Foot Lever Operated
    FEATURES : Large Drench Shower Head Made Of Stainless Steel, SS 304 Pipe, Stainless Steel, Stay Open Ball Valve With Push Plate, Acid, Alkali And Oil Resistant Stainless Steel Receptor Bowl, Twin Soft Flow Automiser Head With Aerators To Control Stream.
    Shower: Operated By Pull Rod
    Eye Wash: Operated By Push Plate/Foot Paddle
    MATERIAL : SS

    5,950.006,200.00
  • CONVENTIONAL GENT CONTROL PANEL

    CONVENTIONAL GENT CONTROL PANEL

    Item specifics

    Condition
    New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is … 
    Brand
    Potter Electric Signal
    Type
    Fire Alarms
    Model
    PFC-6006-R
    MPN
    PFC-6006-R
    Country/Region of Manufacture
    United States
    UPC
    785192021865
    Potter PFC-6006-R – Conventional Fire Panel for Small or Fire Sprinkler Systems – Same Day Shipping (SEALED)
  • TWO WAY PILLAR HYDRANT

    2-Way Pillar  Hydrant

    GZ Industrial Supplies is a Distributor of Hellog tools and other Industrial Tools in Nigeria. Our 2-Way Pillar Double Outlet Fire Hydrant Hellog is used in a high building water seeping system,completed with a check valve,gate valve,fire hose coupling etOutdoor fire hydrant is the water supplier which is connected to the pipeline network of fire system set outside the building.

    The 2-Way Pillar Double Outlet Fire Hydrant Hellog aims at supplying water for fire engines from municipal water supply network or outdoor water supply  network. It can also be directly connected to stream nozzle for putting out fire. The hydrant can be categorized as SS-type and SA-type.The SS-type upper ground fire hydrant has obvious part that higher than ground and can be installed at places where have higher temperatures.It is convenience.The SA-type hydrants are installed underground and wouldn’t affect the appearance of the city.This type is more suitable for cold regions.

    Features of 2- Way Pillar  Hydrant

    • Body material Case iron/mild steel seamless pipe
    • Landing valve material Cooper alloy
    • Landing valve size 2 1/2”
    • Working pressure(Mpa) 10
    • Testing pressure(Mpa) 20
    • Finished Red epoxy painted
    • Inlet 4” Flange
    • Outlet 2 Nos. 2 1/2” landing valve oblique type with female instantaneous connection

    contact us for  product availability in your region.

    TWO WAY PILLAR HYDRANT

  • TWO PILLAR HYDRANT SYSTEM

    TWO PILLAR HYDRANT SYSTEM can be classified into two types, namely, landing type and underground type. Landing type fire hydrant, which is a water supplying facility for firefighting use, is very obvious and conveniently operated with its upper part over the ground while the underground type ones are to installed underground to form harmony with the Pakistan’s environment.

    5,500.006,500.00
  • FIRE HOSE REEL

    FIRE HOSE REEL

    Designed to make easy work of coiling 1” to 3” hose under any condition. Capacity of up to 100′ of single jacket or 50′ of double jacket hose. Capable of Dutch rolls. Attaches to virtually anything with included separate mounting bracket (CSS MB). Trailer Hitch and Wildland Mounting Brackets available as optional add-on accessories for more flexibility in where hose can be coiled. Hose not included.

    MC40 – For 1″-1.5″ hose
    MC65 – For 1.5″-3″ hose

    FIRE HOSE REEL

  • PILLAR HYDRANT FABRICATIONS

    PILLAR HYDRANT FABRICATIONS

    Description

    Item model number DC122012
    Style DC122012 Fire Hydrant Statue Puppy Pee Post Large
    Mounting Type Floor Mount
    Color Large
    Finish Type Painted
    Material Metal
    Country of Origin China
    Item Weight 4 pounds
    Theme Animals
    Pattern Name Container
    Recommended Uses For Product Garden,Home
    Occasion Christmas, Birthday
    Collection Name Animal
    Is Discontinued By Manufacturer No
    Product Dimensions 9.5″D x 11.5″W x 23″H

     

    • FIREFIGHTER’S BEST FRIEND – These vintage collectibles make cool birthday gifts for fire fighters, portable ornaments for the centerpiece of your Christmas village display, or even office garbage cans when stuffed full
    • PERFECT PUPPY PEE POST – This multi-purpose fireman’s water hydrant makes ideal pee post markers for potty training in your outdoor dog yard or as a decorative indoor storage container for doggie supplies, toys and leashes
    • HIGH-QUALITY METAL DECOR – Hand-crafted using real metal construction, our doggy fire hydrant replica is authentically hand-painted with a vintage rustic red color for an aged appearance
    • DESIGN TOSCANO FIRE HYDRANTS – Exclusive to the Design Toscano brand, this cute fire plug hydrant statue makes a perfect gift for a firefighter’s patio, garden lawn or fully decorated man cave
    • Our perfectly sized, large antique style fire hydrant statue measures 11.5″Wx9.5″Dx23″H. 4 lbs.

    PILLAR HYDRANT FABRICATIONS

  • TWO BREECHING INTET VALVES

    2 Breeching Intet Valves manufactured in accordance with BS5041 Part 3, complete with non-return valve, rubber dust cap, 25mm drain valve, cap and chain as standard. They are designed to fit in the dry riser inlet cabinet providing feed of water in an emergency situation to the dry riser outlet valves sited on each floor of the building.

    • Colour: Red RAL3002
    • Inlet Connection: 2 x 2½” Instantaneous male to BS336 with non-return
    • Inlet Cap and chain
    • Outlet Connection: See Options Below
    • Body Material: Cast Iron
    • Drain: 1″ to BS5154 with blank cap and chain
    • Standard: BS5041 : Part 3

    TWO BREECHING INTET VALVES